Carrier 48fc 15 ton.

Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup-

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Carrier Supply Width 15.52 Return Length 37.921 Return Width 15.799 RW RL SW SL CW CL Table 5. Curb matrix Type Trane Lennox Carrier Bryant JCI/York ICP Heil Day and Nigh Goodman Daikin Older Voyager Gas/Electric GCC036-060 ZGB 036-060 48DJ 004-00, 48GJ 006 48HC 004-006, 48HE 004-006 48HJ 004-006, 48KC 004-006 48LJ 004-006, 48LC 004-006 48TC 004-006 ...Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82% …Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat

Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (101 pages) ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages)Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.

Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat 48TC*D/E units for installation in the United States contain use of Carrier's Staged Air Volume (SAV™) 2-speed indoor fan control system. This complies with the U.S. Department of Energy (DOE) efficiency standard of 2018. ... Fig.15 (size 08-16) for base rail details. See Fig. 6 (size 07) for thru-the-base charts.

14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...Are you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...

Carrier West Training – HVAC Training

Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB.

View and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ... Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)Most of Carrier’s 3−12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. ... SEER up to 15.6, EER up to 13.0 IEER’s up to 14.0 with single speed indoor fan motor, and up to 16.0 with SAV (Staged Air Volume) 2−speed/VFDWeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details. carrier chiller data. Check Details. Three Carrier HVAC Units Named Finalists in Consulting-Specifying. Check Details. Carrier 48TCED Manuals | …

Carrier 48GC Series Pdf User Manuals. View online or download Carrier 48GC Series Installation Instructions ... Gas Heat (48FC and 48GC) 8. Controls Quick Set- -Up. 8. Control Set Point and Confirmation Log. 8. Initial Startup. 8. ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector ...Performance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single …This manual is also suitable for: View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A Refrigerant. WeatherMaker Puron 48FC 04 Series air conditioner pdf manual download.Lighter units make easy replacement. Most of Carrier’s 3--12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. Easy to maintain: Easy access handles by Carrier provide quick and easy access to all normally serviced components.Carrier Enterprise Mid-Atlantic Technical Support SiteWe have 2 Carrier 48FC Series manuals available for free PDF download: Controls, Start-Up, Operation And Troubleshooting, Installation Instructions. Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting …

IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unitFull-scale Carrier quality for a variety of equipment types. DXF/CAD templates are full scale 2D drawings of Carrier products. Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. ... 3-28 Ton Rooftop Units – 48/50TC(Q), 48/50KC(Q), 48/50HC(Q), 48/50LC, EnergyX® models. 48 ...

48KC Sizes 04 to 06 Single Packaged Rooftop Units with Gas Heat. Product Data WeatherMaker®. Gas Heat/Electric Cooling Packaged Rooftop Units. 3 to 5 Nominal Tons. 2. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install ...48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... 48FCFM07A1A5-0A0A0 - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Standard STATIC 208/230 ... 48fcfm07a3a5-0a0a0_submittal; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input …4 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA05A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD, PLME, SALE;25SCA5. Up to 15.2 SEER2 for moderate energy savings with standard comfort features. 4.5 out of 5 stars. 32 Reviews. 5 Star. 69%. 4 Star. 22%. 3 Star.RT-PRC094B-EN. Table 1. General data—heating performance – 7.5–12.5 tons. (a)Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards (ANSI). Ratings shown are for elevations up to 2,000 feet.Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;CE - Carrier EnterprisePuron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated withWith solutions from 10 through 500 tons, screw or scroll, Carrier air-cooled chillers are the best choice for your needs. With a wide range of air-cooled chiller scroll and screw types, capacities (10 to 500 tons) and sustainable refrigerant options, Carrier is a leader in the industry. Whether it be non-ozone depleting refrigerant, simple ...SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.

InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...

We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...

ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit. Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. CE - Carrier Enterprise48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged …CE - Carrier EnterpriseAir Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 … Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. For example, using a R--22 gas heat, electric cooling, 6--ton unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust. MCA New = 28.9 amps + 1.7 amps = 30.6 amps If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps, the MCA New is below 35, therefore the …Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;PALM BEACH GARDENS, Fla., March 6, 2023 /PRNewswire/ -- Carrier Global Corporation (NYSE: CARR), the leading global provider of healthy, safe, sus... PALM BEACH GARDENS, Fla., Marc...48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... 48FCFM07A1A5-0A0A0 - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Standard STATIC 208/230 ... 48fcfm07a3a5-0a0a0_submittal; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input …New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.Air Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48HC 04-28 Manual

38AU Gemini™ Commercial Split-System Air-Cooled Condensing Units & 40RU Air Handling Units. 38AUD 10-12 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 15 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 20 Ton Packaged Air Cooled Condenser Units, Dual …CE - carrierenterprise.comAir Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48TCA04---A12 Service And Maintenance Instructions. ... Page 15 Table 2 – Unit Wire/MOCP Sizing Data NO C.O. or UNPWRD C.O. COMBUSTION ...Instagram:https://instagram. how to remove honeywell thermostat from wall platetrish toledo agemath playground rainbow towernj unemployment phone View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,... naics for real estate investmentflood cwf uv color chart A Pg 1 11-22 Replaces: 48FC-8-14-01SB. 48FC 08-16 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society ... shakeys pizza happy hour Time to clean out your attic or garage? Forget about settling for garage sale prices. These days, online auction sites and marketplaces make it easier than ever before to sell your...GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …